伟创变频器型号规格T4电机功率(kW)额定输出电流A制动单元BPELE贝派制动电阻型号制动力矩(%)输入电抗器BPELE贝派输入电抗器型号
三相 380~480V 等级
AC600-T4-R75G-*0.753.00标配BRA-1P502-GE0R100VC-ACL-C-03P7A-T3-2M24BLA3-1EC2-0005
AC600-T4-1R5G-*1.54.0标配BRA-03P02-D00R100VC-ACL-C-03P7A-T3-2M24BLA3-1EC2-0005
AC600-T4-2R2G-*2.26.0标配BRA-04P02-BE0R100VC-ACL-C-05P5A-T3-2M18BLA3-1EC2-0010
AC600-T4-004G-*4.010.0标配BRA-05P02-AE0R100VC-ACL-C-0009A-T3-1M85BLA3-1EC2-0010
AC600-T4-5R5G-*5.513.0标配BRA-06P02-A00R100VC-ACL-C-0013A-T3-1M56BLA3-1EC2-0015
AC600-T4-7R5G-*7.517.0标配BRA-08P02-0GER100VC-ACL-C-0018A-T3-1M00BLA3-1EC2-0020
AC600-T4-011G-*1125标配BRA-1P203-0E0R100VC-ACL-C-0024A-T3-M520BLA3-1EC2-0030
AC600-T4-015G-*1532标配BRA-1P503-0D0R100VC-ACL-C-0034A-T3-M400BLA3-1EC2-0035
AC600-T4-018G-*18.538.0标配BRA-02P03-0CBR100VC-ACL-C-0038A-T3-M350BLA3-1EC2-0040
AC600-T4-022G-*2245标配BRA-02P03-0CBR100VC-ACL-C-0050A-T3-M260BLA3-1EC2-0050
AC600-T4-030G-*3060选配BRA-03P03-0BDR100VC-ACL-C-0060A-T3-M240BLA3-1EC2-0060
AC600-T4-037G-*3775选配BRBW-04P03-0B0R100VC-ACL-C-0075A-T3-M235BLA3-1EC2-0080
AC600-T4-045G-*4590选配BRBW-4P503-0AFR100VC-ACL-C-0091A-T3-M170BLA3-1EC2-0090
AC600-T4-055G-*55110选配BRBW-06P03-0ACR100VC-ACL-A-0112A-T3-M110BLA3-1EC2-0110
AC600-T4-075G-*75150选配BRBW-08P03-00JR100VC-ACL-A-0150A-T3-M082BLA3-1EC2-0150
AC600-T4-090G-*90180选配BRBW-10P03-0FRH100VC-ACL-A-0200A-T3-M070BLA3-1EC2-0200
AC600-T4-110G-*110210选配BRBW-12P53-0FRB100VC-ACL-A-0224A-T3-M056BLA3-1EC2-0250
AC600-T4-132G-*132250外置BRBW-15P03-0DRG100VC-ACL-A-0280A-T3-46U6BLA3-1EC2-0300
AC600-T4-160G-*160310外置BRBW-15P03-0CRJ100VC-ACL-A-0315A-T3-38U8BLA3-1EC2-0350
AC600-T4-185G-*185340外置BRBW-20P03-0CRC100VC-ACL-A-0400A-T3-36U8BLA3-1EC2-0400
AC600-T4-200G-*200380外置BRBW-20P03-00CR100VC-ACL-A-0400A-T3-36U8BLA3-1EC2-0400
AC600-T4-220G-*220415外置BRBW-20P03-0BRG100VC-ACL-A-0450A-T3-33U3BLA3-1EC2-0450
AC600-T4-250G-*250470外置BRBW-25P03-0BRD100VC-ACL-A-0560A-T3-26U4BLA3-1EC2-0560
AC600-T4-280G-*280510外置BRBW-25P03-00BR100VC-ACL-A-0560A-T3-26U4BLA3-1EC2-0560
AC600-T4-315G-*315600外置BRBW-30P03-0ARH100VC-ACL-A-0630A-T3-23U3BLA3-1EC2-0630
AC600-T4-355G-*355670外置BRCW-40P03-0ARE100VC-ACL-A-0720A-T3-18U4BLA3-1EC2-0720
AC600-T4-400G-*400750外置BRCW-50P03-0ARB100VC-ACL-A-0720A-T3-18U4BLA3-1EC2-0720
AC600-T4-450G-*450800外置BRCW-50P03-0ARB100VC-ACL-A-1000A-T3-14U7BLA3-1EC2-1000
AC600-T4-500G-*500860外置BRCW-50P03-00AR100VC-ACL-A-1000A-T3-14U7BLA3-1EC2-1000
AC600-T4-560G-*560990外置BRCW-50P03-00AR100VC-ACL-A-1250A-T3-11U6BLA3-1EC2-1200

上表中所述制动电阻阻值、电阻功率是按照普通惯量负载和间歇制动方式核定的。如果需要使用在大惯量、长时间频繁制动的场合,请根据所选变频器规格、制动单元的额定参数,适当调整制动电阻阻值和电阻功率。
表中外置连接制动单元;若变频器内置有制动单元,则无需再外置连接制动单元。若外置连接制动单元,则制动电阻选型需要基于外接的制动单元以及变频器自身的限制,制动电阻的选型需要做其规格确认再使用。制动电阻的阻值不可小于制动单元Rmin

超过样本范围或者位能类负载如爬坡、上下提升类、长时制动请与我们联系。不同工况下制动电阻的功率不一样,功率过小会导致电阻过热而引发火灾,影响设备运行安全,因而要根据实际情况进行功率选型调整。